As power supply switching frequencies increase, higher loop crossover frequencies are necessary to keep pace with the escalating load transient slew rate demands, and to reduce the number and size of filter components. For voltage-mode-controlled supplies, the voltage loop error amplifier must work harder to provide its compensating gain loop contribution. ..