Pressure Transmitter Data Acquisition System 1B31,18 bit A / D converter AD1170 and MCS-51 microcontroller
Description: The pressure transmitter circuit data acquisition system utilizes the 1B31, an 18-bit A/D converter (AD1170), and an MCS-51 microcontroller. The configuration, as depicted in the accompanying diagram, features a full-scale output voltage of 10 mV from the pressure transmitter connected to the 1B31. The 1B31 is set to a gain of 500, resulting in an output voltage range of 0 to 5 V. The excitation voltage is established at +5 V. To compute the ratio, the voltage from the AD1170 is also used as a reference voltage, initialized through the ECAL command, which sets the AD1170's full-scale input voltage. Periodic calibration of the A/D converter allows for tracking changes in the reference voltage alongside the output characteristics. The system benefits from a high common-mode rejection ratio due to the implementation of low-pass filtering and A/D conversion techniques. The microcontroller initializes the AD1170 and compensates for fixed offset voltages generated by bridge asymmetry, eliminating the need for a zero potentiometer or software-based zeroing.
The pressure transmitter circuit is designed to accurately capture and process pressure data through a systematic approach involving both hardware and software components. The 1B31 amplifier is configured to amplify the small signal from the pressure transmitter, ensuring that it is within the operational range of the A/D converter. The gain setting of 500 is critical as it allows for the full-scale output voltage of the transmitter, which is only 10 mV, to be effectively scaled to a 0-5 V range suitable for digital processing.
The AD1170 A/D converter is a pivotal element in this system, providing high-resolution data acquisition with its 18-bit resolution. The initialization command ECAL serves a dual purpose: it not only sets the reference voltage for accurate readings but also ensures that the system can adapt to any variations in the reference voltage over time. This adaptability is crucial for maintaining measurement integrity in varying operational conditions.
The microcontroller, based on the MCS-51 architecture, plays an essential role in managing the data acquisition process. It handles the initialization of the AD1170, processes the incoming digital signals, and performs necessary computations to derive meaningful pressure measurements. The inclusion of a low-pass filter in the design aids in reducing noise and enhancing the signal-to-noise ratio, which is vital for applications requiring precise measurements.
Furthermore, the system's design minimizes the effects of fixed offset voltages that can arise from the bridge's asymmetry, thereby improving accuracy without the need for manual calibration adjustments via a zero potentiometer. This feature simplifies the setup and maintenance of the system, making it more user-friendly and reliable in practical applications. Overall, this pressure transmitter circuit represents a robust solution for high-accuracy pressure measurement and data acquisition in various industrial and research settings.Pressure transmitter circuit data acquisition system by 1B31,18 bit A / D converter AD1170 and MCS-51 microcontroller configuration shown in Fig. Will be a full-scale output voltage of 10mV pressure transmitter connected to the 1B31, 1B31 set a gain of 500 times, the output voltage range is 0 ~ 5V. Excitation voltage is set to + 5V, in order to perform computing the ratio, the AD1170 voltage also serves as a reference voltage by the voltage of the initialization command ECAL as AD1170 full-scale input voltage, then by periodically calibrating the A / D converter You can follow the reference voltage changes, with the ratio of output characteristics.
As a result of the low-pass filter and A / D conversion technology, so the system has a high common-mode rejection ratio. Use microcontroller AD1170 is initialized, but also to eliminate fixed offset voltage generated by the bridge asymmetric, so do not have to use zero potentiometer (or software) zeroing up.
Data acquisition is the process by which events in the real world are sampled and translated into machine-readable signals. Data acquisition typically involves sensors, transmitters and other instruments to collect signals, waveforms etc. to be processed and analyzed with a...
A low-cost, high-speed monolithic analog multiplexer. The system operates by selecting a channel and initiating a conversion at a gain (G) of 1. It then examines the most significant bit (MSB) of the conversion result. If the MSB equals 1,...
Converters and data sampling: A 12-bit A/D converter, AD574, is interfaced with an 8031 microcontroller circuit. Parameters are measured by a multi-way switch after a CD4051 strobe signal is sent to the sample/hold input device. The selection of the input...
The technology of data acquisition is an important branch of information science. It is not only employed in intelligent instruments but is also widely used in modern industrial production and military science. This technology is essential for process control, condition...
A design example for a portable data acquisition system is provided, which significantly simplifies the circuit design task.
The portable data acquisition system is designed to capture, process, and store data from various sensors and input devices. This system typically includes...
This application note outlines the design of a PC-based, 14-bit data acquisition system. It adopts a systematic approach, incorporating all essential components: analog, digital, hardware, and software. The document elaborates on each phase, emphasizing the testing of individual systems prior...
The Wildcard requires a minimum of 8 volts on the V+Raw power rail, which must not exceed 26 volts. When using the Docking Panel or Power Dock, the V+Raw rail is automatically connected. If not using a dock, manual connection...
The HI-506 multiplexer functions as an analog input selector, which is controlled by a binary counter to select the appropriate channel. The HA-5330 serves as a high-speed sample and hold circuit. The sample/hold control is connected to the status (STS)...
This diagram illustrates a high-speed data acquisition system featuring eight differential inputs and a 12-bit resolution utilizing the AM-543. When the control logic is synchronized such that the Sample-Hold-ADC section converts one analog value while the mux-amplifier section stabilizes for...
We use cookies to enhance your experience, analyze traffic, and (if you allow) serve personalized ads.
By clicking Accept All, you agree to our use of cookies.
Learn more