Delayed Alarm Circuit


Posted on Oct 20, 2012

The alarm/sensor circuit shown is built around two SCRs, a transistor, a 4049 hex inverter, and a few support components, all of which combine to form a closed-loop detection circuit with a delay feature. The delay feature allows you to enter a protected area and deactivate the circuit before the sounder goes off.Assuming that the protected area has not been breached (i.e., SI is in its normally-closed position), when power is first applied to the circuit, -a positive voltage is applied to the input of Ul-a through SI and R1, causing its output to go low. That low is applied to the gate of SCR1, causing it to remain off. At the same time, C6 rapidly charges toward the supply rail through S2, LED2, R4, and D3. The charge on C6 pulls pin 5 of Ul-b high, causing its output at pin 4 to be low.


Delayed Alarm Circuit
Click here to download the full size of the above Circuit.

That low is applied to the base of Ql, keeping it off. Because no trigger voltage is applied to the gate of SCR2 (via Ql), the SCR remains off and BZ1 does not sound.But should SI open, the input of Ul-a is pulled low via R9, forcing the output of Ul-a high, lighting LED1. That high is also.applied to the gate of SCR1 through D1 and R3, causing SCR1 to turn on. With SCR1 conducting, the charge on Co decays, the input of Ul-b at pin 5 is pulled low, forcing its output high, slowing charging C8 through R8 to a voltage slightly less than the positive supply rail. Transistor Ql remains off until C8 has charged to a level sufficient to bias Ql on, allowing sufficient time to enter the protected area and disable the alarm before it sounds. Once C8 has developed a sufficient charge, Ql turns on and supplies gate current to SCR2 through R6, causing the SCR to turn on and activate BZ1. If the circuit is reset before the delay has timed out, no alarm will sound. The delay time can be lengthened by increasing the value of either or both C6 and R5; decreasing the value of either or both of those components will shorten the delay time. All of the switches used in the circuit are of the normally-closed (NC) variety. Switch SI can be any type of NC security switch. Switch S2 can be either a pushbutton or toggle switch. Because S3 is used to disable the sounder (BZ1) only, anything from a key-operated security switch to a hidden toggle switch can be used.




Leave Comment

characters left:

New Circuits

.

 


Popular Circuits

from 42 to 88 Mhz Band
Serial Programmer for AVR microprocessors
Variable-slope-compressor-expander
rf detector electronic project circuit design using 2n2222 transistors
sequencer
DA24QSDS
MSF detector - turning the radio signal into data
AN12979A Audio Power Amplifier
A Low-Frequency Crystal Controlled Oscillator
Klipsch Promedia V5.1 Amplifier Repair
Digital HF Antenna Analyser
Precision polarity switching circuit by conventional elements
Conducting pipe control rechargeable delay circuit
Differential amplifier circuit



Top