Scope-extender


Posted on Aug 24, 2012

The adapter allows four inputs to be displayed simultaoeously on a single trace scope. For low-frequency signals, less than 500Hz, the adapter is used in the chop mode at a frequency of 50 kHz. The clock can be run faster, but switching glitches and the actual switching time of the DG201A limit the maximum frequency to 200 kHz. High frequencies are best viewed in the alternate mode, with a clock frequency of 200 Hz.


Scope-extender
Click here to download the full size of the above Circuit.

When the clock is below 100 Hz, trace flicker becomes objectionable. One of the four inputs is used to trigger the horizontal trace of the scope.